Belden Infinity Flexible Automation Cables Offer Exceptional Performance, Superior Flexibility and Extended Cable Life In Near-constant Motion Applications

car_mfg_robotBelden Infinity is a complete line of control, data, video and power cables specifically designed to handle the rigorous speeds and near-constant motion encountered in automated equipment such as robots, pick and place machines, automatic handling systems, multi-axis machine tools and conveyor systems.

The product series includes the following cable types:

  • CTC+ – The C-TC+ series is designed for C-track and extreme flex applications up to 9 million flex cycles (based on proper installation techniques in a C-track cable guide).  This series utilizes super fine stranding and some of the tightest lay lengths allowed by UL, providing outstanding flex life.
  • FCC – The FCC series is a cost effective alternative for C-track and moderate flexing applications rated up to 1 million flex cycles (based on proper installation techniques in a C-track cable guide). (LINKS TO attached page – anchor it)
  • Flex Data Cables – These cables are designed for industrial applications where precise data transmission is combined with high-flexing.  They are ideal for effective operation of computer controlled equipment or other automated production processes, even in harsh environments.
  • Flex Vision – These continuous flex video cables are designed specifically for machine vision applications.  They are ideal for motion-controlled video and inspection and measurement equipment.

NP218_product

Belden Infinity Cable – Features and Benefits

When the application demands highly flexible cables offering exceptional cable life and performance, specify Belden Infinity.  Key cable attributes include:

  • Reduced Cable Memory – Belden Infinity’s unique design and neutralized cabling, results in cables that are relaxed, with almost no memory.
  • Greater Flex Life – Superior flexibility means that these cables are able to handle the vigorous motions and high speeds encountered in automated equipment.
  • Greater System Uptime – Belden combined specialized manufacturing techniques with precision copper stranding and rugged insulation and jacketing compounds to maximize the cables’ flex life and reliability.
  • No Talc Problems – Unlike the potentially harmful talc used in other cables, Belden’s inert, non-irritating slipper compound facilitates flexing and also complies with OSHA regulations.  It’s safer for employees and operators and is less likely to contaminate solder joints or mechanical compounds.
  • CE Conformity – All Belden Infinity cables are CE marked per the Conformite Europeenne low voltage directive, allowing European market access.
  • Custom Designs – Just ask.

Belden Infinity® Flexible Automation Cable

C-TC+ Control Cables/600V for Extreme Flexing (9 Million Flex Cycles)

20 AWG Stranded (74×38) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7101A 3 Conductors
7102A 4 Conductors
7105A 9 Conductors
7106A 12 Conductors
7107A 18 Conductors
7108A 25 Conductors

20 AWG Stranded (74×38) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7106AS 12 Conductors

18 AWG Stranded (114×38) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7110A 3 Conductors
7113A 7 Conductors
7115A 12 Conductors
7116A 18 Conductors
7117A 25 Conductors

18 AWG Stranded (114×38) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7111AS 4 Conductors
7115AS 12 Conductors

16 AWG Stranded (190×38) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7122A 3 Conductors
7125A 7 Conductors
7126A 9 Conductors
7127A 12 Conductors
7128A 18 Conductors
7129A 25 Conductors

16 AWG Stranded (190×38) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7123AS 4 Conductors

14 AWG Stranded (266×38) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7136A 4 Conductors

14 AWG Stranded (266×38) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7136AS 4 Conductors

12 AWG Stranded (413×38) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7145A 4 Conductors

FCC Control Cables/600V for Moderate Flexing (1 Million Flex Cycles)

20 AWG Stranded (10×30) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7400A 2 Conductors
7401A 3 Conductors
7402A 4 Conductors
7403A 5 Conductors
7404A 7 Conductors
7405A 9 Conductors
7406A 12 Conductors
7407A 18 Conductors
7408A 25 Conductors

20 AWG Stranded (10×30) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7401AS 3 Conductors
7402AS 4 Conductors
7403AS 5 Conductors
7404AS 7 Conductors

18 AWG Stranded (16×30) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7409A 2 Conductors
7410A 3 Conductors
7411A 4 Conductors
7412A 5 Conductors
7413A 7 Conductors
7414A 9 Conductors
7415A 12 Conductors
7416A 18 Conductors
7417A 25 Conductors
7418A 34 Conductors
7419A 41 Conductors
7420A 50 Conductors

18 AWG Stranded (16×30) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7411AS 4 Conductors
7413AS 7 Conductors
7415AS 12 Conductors
7416AS 18 Conductors
7417AS 25 Conductors

16 AWG Stranded (26×30) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7421A 2 Conductors
7422A 3 Conductors
7423A 4 Conductors
7424A 5 Conductors
7425A 7 Conductors
7426A 9 Conductors
7427A 12 Conductors
7428A 18 Conductors
7429A 25 Conductors
7430A 34 Conductors

16 AWG Stranded (26×30) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7423AS 4 Conductors
7427AS 12 Conductors
7428AS 18 Conductors

14 AWG Stranded (41×30) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7434A 2 Conductors
7435A 3 Conductors
7436A 4 Conductors
7438A 7 Conductors
7439A 9 Conductors
7440A 12 Conductors
7442A 25 Conductors

14 AWG Stranded (41×30) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7436AS 4 Conductors
7438AS 7 Conductors

12 AWG Stranded (65×30) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7444A 3 Conductors
7445A 4 Conductors

12 AWG Stranded (65×30) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7445AS 4 Conductors

10 AWG Stranded (105×30) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7447A 4 Conductors

10 AWG Stranded (105×30) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7447AS 4 Conductors

8 AWG Stranded (168×30) Bare Copper Conductors, Unshielded, PVC Insulation, PVC Jacket; UL AWM Style 2587, 600V 90°C
7450A 4 Conductors

8 AWG Stranded (168×30) Bare Copper Conductors, Tinned Copper Braid Shield (85% Coverage), PVC Insulation, PVC Inner & Outer Jackets; UL AWM Style 2587, 600V 90°C
7450AS 4 Conductors

Flex Data Cables/300V (1 Million Flex Cycles); EIA-485 Type

24 AWG Stranded (41×40) Bare Copper Conductors, Twisted Pairs, Overall Beldfoil® Shield (100% Coverage) + TC Braid Shield (85% Coverage), Foam Polyethylene Insulation, PVC Jacket; 300V 60°C
7200A 1 Pair
7201A 2 Pair
7202A 3 Pair
7203A 4 Pair
7206A 1 Pair

75-Ohm Flex Vision Coax Cables/30V (1 Million Flex Cycles)

Sub-Mini Type, 30 AWG Stranded (7×38) Tinned Cadmium Bronze Conductor, Tinned Copper “French Braid” (95% Coverage) Shield, Foam Polyethylene Insulation, Matte Blue Belflex® Jacket; UL AWM Style 1354
7500A

Mini Type, 25 AWG Stranded (19×38) Bare Copper Conductor, Tinned Copper “French Braid” (95% Coverage) Shield, Foam Polyethylene Insulation, Matte Blue Belflex Jacket; UL AWM Style 1354
7501A

RG-59 Type, 22 AWG Stranded (19×34) Bare Copper Conductor Conductor, Tinned Copper “French Braid” (95% Coverage) Shield, Foam Polyethylene Insulation, Matte Blue Belflex Jacket; UL AWM Style 1354
7502A

RG-6/U Type, 20 AWG Stranded (7x15x40) Bare Copper Conductor, Tinned Copper “French Braid” (95% Coverage) Shield, Foam Polyethylene Insulation, Matte Blue Belflex Jacket; UL AWM Style 1354
7503A

RG-11Type, 16 AWG Stranded (7x37x40) Bare Copper Conductor, Tinned Copper “French Braid” (95% Coverage) Shield, Foam Polyethylene Insulation, Matte Blue Belflex Jacket; UL AWM Style 1354
7504A